Shop
Showing 217–228 of 847 results
-
Low Frequency Conducted Immunity Simulator
Coupling Networks for Testing of Immunity to Conducted, Common-mode Disturbances CN 416M4N-32
Model:CN 416M4N-32
CN 416M4-32 is specifically designed to meet the requirements as per Standard IEC 61000 – 4 -16:2015, which can be applied to 4-line cables, with its voltage of immunity to coupling conducted common mode disturbance up to 300V.
Model:CN 416M4N-32
CN 416M4-32 is specifically designed to meet the requiremen
...(0 reviews) -
Low Frequency Conducted Immunity Simulator
Balanced / Unbalanced Impedance Converter Balun 50/10
Model:Balun 50/10
Balanced / Unbalanced impedance converter Balun 50/10 is designed according to IEC 61000-4-19:2014, capable of converting balanced signal to unbalanced signal with the impedance from 10Ω to 50Ω at the same time.
Model:Balun 50/10
Balanced / Unbalanced impedance converter Balun 50/10 is des
...(0 reviews) -
Low Frequency Conducted Immunity Simulator
Common-Mode Conducted Disturbances Simulator CDS 300
Model:CDS 300The CDS 300 conducted, common mode disturbances simulator can be controlled by CoreLab control software to conduct various functional tests in the frequency range from 0 Hz (DC) to 165 kHz.
Model:CDS 300
...
The CDS 300 conducted, co(0 reviews) -
Low Frequency Conducted Immunity Simulator
CDNs for Test of Immunity to Common-mode Conducted Disturbances
Model:CDN 416T8
The CDNs for Test of Immunity to Common-mode Conducted Disturbances CDN 416T8 is designed as per IEC 61000-4-16:2015 and used to test the immunity to conducted.
Model:CDN 416T8
The CDNs for Test of Immunity to Common-mode Conducted Disturb
...(0 reviews) -
Low Frequency Conducted Immunity Simulator
CDNs for Test of Immunity to Common-mode Conducted Disturbances CDN 416T2
Model:CDN 416T2
The coupling/decoupling networks CDN 416T2 is designed according to IEC 61000-4-16:2015 and applied to 2-line tests for immunity to conducted.
Model:CDN 416T2
The coupling/decoupling networks CDN 416T2 is designed accordi
...(0 reviews) -
Low Frequency Conducted Immunity Simulator
CDNs for Test of Immunity to Common-mode Conducted Disturbances
Model:CDN 416T4The coupling/decoupling networks CDN 416T4 is designed according to IEC 61000-4-16:2015 and applied to 4-line tests for immunity to conducted.
Model:CDN 416T4
...
The coupling/decoupling(0 reviews) -
Low Frequency Conducted Immunity Simulator
Common Mode Conduction Anti-interference Coupling Network CN 416M5-32
Model:CN 416M5-32The CN 416M5-32 coupling network is suitable for (common mode conducted immunity) 5-wire cables, and its coupled common mode conducted immunity voltage can reach 300V.
Model:CN 416M5-32
...
The CN 416M5-32 coupling network is suitable for (c(0 reviews) -
Low Frequency Conducted Immunity Simulator
Coupling/Decoupling Networks for Immunity to Conducted, Differential Mode Disturbances CDN 419M3-32
Model:CDN 419M3-32The CDN 419M3-32 is designed in accordance with IEC610000-4-19:2014 and applicable to immunity to conducted.
Model:CDN 419M3-32
...
The CDN 419M3-32 is(0 reviews) -
Low Frequency Conducted Immunity Simulator
Common Mode Conduction Anti-interference Coupling Network CN 416M2M3-32
Model:CN 416M2M3-32
The CN 416M2/M3-32 coupling network is suitable for (common mode conducted immunity) 2-wire or 3-wire cables, and its coupled common mode conducted immunity voltage can reach 300V.
Model:CN 416M2M3-32
The CN 416M2/M3-32 coupling network is suitable for (commo
...(0 reviews) -
Low Frequency Conducted Immunity Simulator
Common Mode Conduction Anti-interference Coupling Network CN 416M5-100
Model:CN 416M5-100The CN 416M5-100 coupling network is suitable for (common mode conducted immunity) 5-wire cables, and its coupled common mode conducted immunity voltage can reach 300V.
Model:CN 416M5-100
...
The CN 416M5-100 cou(0 reviews) -
Low Frequency Conducted Immunity Simulator
Common Mode Conduction Anti-interference Coupling Network CN 416M4N-32(690V)
Model:CN 416M4N-32(690V)
The CN 416M4N-32 coupling network is suitable for (common mode conduction anti-interference) 2-wire or 3-wire cables, and its coupling common mode conduction anti-interference voltage can reach 300V. Design strictly in accordance with the requirements of IEC 61000-4-16:2015 standard.
Model:CN 416M4N-32(690V)
The CN 416M4N-32 coupling network is suitable for (co
...(0 reviews) -
Low Frequency Conducted Immunity Simulator
Differential Mode Conducted Interference Simulator RSG 40C20(DMS)
Model:RSG 40C20(DMS)
RSG 40C20 is a simulator for differential mode conducted disturbance immunity testing that complies with the requirements of IEC 61000-4-19/GB/T 17626.19 and JJF 1245.4-2019 standards.
Model:RSG 40C20(DMS)
RSG 40C20 is a simulator for differential mode conducted
...(0 reviews)