EMI-EMC testing

ISO/IEC 17025:2017 Accredited

EMI-EMC testing, up to 40 GHz

Salicon Nano Technology runs an in-house EMI/EMC lab covering automotive & EV, commercial/industrial/IT, and defence & aerospace test standards — under a single accredited scope, at one facility.

Accreditation & Facility

Certificate No: T‑0042

Standard: ISO/IEC 17025:2017

Validity: 29 March 2030

Facility Location: Ghaziabad, Delhi NCR

Frequency Coverage: 150 kHz – 40 GHz

72 accredited test methods across automotive, industrial, and defence — all under one roof.

ISO/IEC 17025:2017 Accredited

One accredited scope, three worlds of product

72 accredited test methods spanning emissions and immunity, run at a single permanent facility — so automotive, industrial and defence programmes don’t need to split their EMC campaign across labs.

Up to 40GHz

Combined frequency coverage

72

Accredited test methods

±30kV

Max ESD immunity level

100%

Permanent, in-house facility

Inside the lab

A full anechoic chamber, built for real DUTs

Radiated emission and immunity testing on drones, EV powertrain components and full sub-assemblies — not just bench-top parts.

Accredited Scope

What we test, by industry

Grouped from our ISO/IEC 17025:2017 scope of accreditation (Certificate T-0042) so you can find your standard in seconds.

Automotive & EV Testing

Component, ESA and vehicle-level EMC to CISPR 25, ISO 11452, ISO 7637, ISO 16750, AIS 004/138 and IEC 61851 for EV charging systems.

Automotive & EV Testing

Component/ESA emissions on HV power lines — current & voltage probe methods, plus ALSE radiated emissions.

Range: 150kHz–2.5GHz

EV AC charging system (AIS 138 / IEC 61851)

Conducted emission, harmonic current, DC voltage dips & variations, EFT/burst, high-energy immunity and conducted RF/BCI on charging equipment.

Range: 150kHz–230MHz

Automotive electrical immunity

12V/24V transient and supply-line immunity to ISO 16750-2 and ISO 7637-2, including load-dump pulses.

Pulse: −150V to +200V

Automotive conducted transient emission

Transient emission on the vehicle supply line per ECE R10 / AIS 004 (Part 3) and ISO 7637-2.

Range: ±0.2V–±400V

ESA & vehicle RF susceptibility / BCI

Bulk current injection and radiated RF susceptibility on electrical/electronic sub-assemblies to ISO 11452-2/4.

Range: 1MHz–18GHz

Vehicles, boats & IC engines

Conducted emission testing on complete vehicles, boats and internal combustion engines per CISPR 25.

Range: 150kHz–108MHz

Commercial / Industrial & IT Testing

Full emissions and immunity suite for multimedia/IT, industrial drives, lighting, appliances, medical/ISM and telecom equipment.

Multimedia & IT equipment (CISPR 32)

Conducted and radiated emission testing for multimedia and information technology equipment.

Range: 150kHz–6GHz

ESD, RF & transient immunity

Electrostatic discharge, radiated/conducted RF immunity, EFT/burst and surge immunity to the IEC 61000-4 series.

Range: 1MHz–18GHz

Power quality immunity

Voltage dips, short interruptions, flicker, harmonics and magnetic-field immunity for general electrical/electronic products.

Range: 150kHz–108MHz

Industrial drive systems (IEC 61800-3)

Conducted emission and immunity testing for adjustable-speed electrical power drive systems.

Range: 150kHz–6GHz

Lighting & household equipment

Conducted and radiated emission for lighting equipment (CISPR 15) and household appliances/power tools (CISPR 14-1).

Range: 1MHz–18GHz

Medical, ISM & network telecom

Radiated emission for medical/ISM equipment (IEC 60601-1-2) and conducted/radiated immunity for network telecom equipment (GR-1089).

Range: 150kHz–108MHz

Defence & Aerospace Testing – MIL-STD-461E/F/G

Full RE/RS/CS/CE test suite for defence subsystems and equipment under MIL-STD-461E, F and G.

RE101 – radiated emissions, magnetic field

Magnetic-field radiated emissions from defence subsystems and equipment.

Range: 150kHz–6GHz

RE102 – radiated emissions, electric field

Electric-field radiated emissions across the defence subsystem frequency band.

Range: 1MHz–18GHz

RE103 – antenna spurious & harmonic outputs

Radiated emissions covering antenna spurious and harmonic outputs.

Range: 150kHz–108MHz

RS101 / RS103 – radiated susceptibility

Low-frequency magnetic-field and high-frequency electric-field radiated susceptibility.

Range: 150kHz–6GHz

CS101–CS118 – conducted susceptibility

Full conducted-susceptibility group — CS101, 103, 104, 105, 106, 109, 114, 115, 116 and 118.

Range: 1MHz–18GHz

CS118 – electrostatic discharge

Electrostatic discharge test on defence equipment per MIL-STD-461G, section 5.16.

Range: 150kHz–108MHz